Digital Display Intelligent Temperature Controller Humidifying and Dehumidifying Greenhouse Incubation Controller Humidity Controller
$14.00 – $18.00
- Description
- Size Guide
- Additional information
- Reviews (0)
Description
Description
product description
- Control range:1%RH-99%RH
- Load power:10A/AC220V
- Measurement range:-20℃~80℃
- Humidity range:1%RH-99%RH
- Measurement error:±3%RH(environment temperature at 25℃)
- Temperature precision:1℃ Humidity precision:1%RH
- Display accuracy:1%RH
- Power Supply:DC12V//220V(Choose)
- Output type:10A relay output probe type
- Temperature: NTC precision ±1℃
- Humidity:resistance type sensor precision ±3℃
- Dimension:90*60*26.5mm(L*W*H)
- Temperature control object:one channel temperature(heating and refrigeration ventilator)
- Or humidity(Dehumidify or humidify electrical appliance)
- Probe line length:standard 1.5m
- Permanent memory of parameter:set the all parameter with permanent memory
- Power failure at the operation time:run after the power supply.
- Working environment: temperature 0-55℃ humidity90%RH without condensation
Menu code description:
Humidity control setting:Press Set keyboard one time,press three second enter into setting menu after humidity display flashing,it will display code HC.Press "▲ "keyboard or "▼"keyboard can cyclical selection HC-CP-PU-CA-HP parameter code.Please press Set keyboard if you need enter into a code,press "▲ "keyboard or "▼"keyboard to modify the required numerical for five seconds then return automatically.
Press "SET" keyboard twice enter into setting menu after temperature display flashing,and display code HC,press "▲ "keyboard or "▼"keyboard can cyclical selection HC-CP-PU-CA-HP
parameter code,please press "SET " keyboard if you need enter into one code ,press "▲ "keyboard or "▼"keyboard to modify the required numerical for five seconds then return automatically.
Dehumidification control: The way of mode control (code HC) it will be dehumidification control when setting as C.For example,set the humidity control value as 50% RH and humidity difference as 5%,relay start output,When environment humidity value ≤setting humidity value(50%RH),relay close output.
Damping control:The way of humidity control (code HC) ,set H as damping mode,for example,set the humidity control value as 50%RH and humidity difference as 5%RH. When temperature humidity value ≤setting value(50%RH)-difference/(5%RH) ,relay start output.when temperature humidity ≥setting value(50%RH),relay stop output.
HC:mode selection,H means humidifying mode,C means dehumidificatio mode.
D:return difference, start the humidify when in the humidifying mode=displaying humidity-return difference.start the humidify when in dehumidification mode=displaying humidity + return difference.
PU:Delay to start.when relay stop output and start timing.the interval time of next boot must greater than delay start time to avoid start frequently.
HP:Humidity upper limit alarm:when humidity exceed upper limit alarm,digital tube displaying "-H-",humidity lower than alarm setting value it will return back from alarm automatically.
LS;Humidity lower limit alarm:When humidity exceed lower limit,digital tube display"-L-",humidity higher than alarm setting value it will return back from alarm automatically.
CA:Humidity correction:Humidity correction value plus displaying value.For example:humidity display 50% RH correction humidity increase 5% RH,then display humidity will be 55%RH.
Heating mode:Mode control way (code HC) set as H ,it is heating mode.For example,set control heating value as 35℃,temperature return difference is 2°.when environment humidity value ≥setting temperature value(35℃)-return difference(2 ℃),relay start output.when humidity value≤setting humidity value (35℃),relay close output.
Cooling control:The way of mode control ,set (HC code) as C ,it is cooling mode.For example,set cooling as 35 ℃ and temperature return difference as 2 ℃.When environment value ≥ setting temperature value (35℃)+return difference(2℃),relay start output:when environment humidity value≤setting humidity value(35 ℃),relay stop output.
HC:Mode selection,C means cooling mode,H means heating mode.
D:return difference,start temperature when in heating mode= displaying temperature"-return difference.Start temperature when in cooling mode=displaying temperature+return difference.
PU:Delay to start,When relay stop output and start timing,the interval of time must greater than delay start time to avoid start frequently.HP:temperature upper limit alarm:when temperature exceed upper limit alarm,digital tube display"HHH",temperature lower than alarm setting it will return back from alarm automatically.
LS:temperature lower limit alarm:when temperature exceed than lower limit alarm,digital tube display "LLL",temperature higher than alarm setting it will return back from alarm automatically.
CA temperature correction:Humidity correction value plus display humidity value,for example:humidity displaying 35℃ ,correction humidity increase 5℃,then temperature should be 35℃.
Reset:Press left up and down keyboard until screen displaying 888,then it will coma back to factory reset.
Noted:12v/24v/220v mode of connection are same.12v wire connection need to make clear about negative and positive anodes.
Size Guide

size | chest(in.) | waist(in.) | hips(in.) |
---|---|---|---|
XS | 34-36 | 27-29 | 34.5-36.5 |
S | 36-38 | 29-31 | 36.5-38.5 |
M | 38-40 | 31-33 | 38.5-40.5 |
L | 40-42 | 33-36 | 40.5-43.5 |
XL | 42-45 | 36-40 | 43.5-47.5 |
XXL | 45-48 | 40-44 | 47.5-51.5 |
Additional information
Additional information
Voltage | 12V, 24V, 220V |
---|
Reviews (0)
Be the first to review “Digital Display Intelligent Temperature Controller Humidifying and Dehumidifying Greenhouse Incubation Controller Humidity Controller” Cancel reply
You must be logged in to post a review.
Reviews
There are no reviews yet.